UFC 3-310-01
25 May 2005
OCCUPANCY OR USE
UNIFORM
CONCENTRATED
kPa
(psf)
kN
(lbs.)
17. Dining rooms and restaurants
4.8
100
---
---
18. Decks
Same as
Same as
Occupancy
Occupancy
---
---
Servedh
Servedh
19. Dwellings (see residential)
---
---
---
---
20. Elevator machine room grating
---
---
1.33
300
(on area of 2600 mm2 (4 in.2 ))
21. Finish light floor plate construction
(on area of 650 mm2 (1 in.2 ))
---
---
0.89
200
22. Fire escapes
4.8
100
---
---
On single-family dwellings only
1.9
40
23. Galleys
Dishwashing rooms
14.4
300
General kitchen area
12.0
250
Provision storage (not
---
---
refrigerated)
9.6
200
Preparation room
Meat
12.0
250
Vegetable
4.8
100
24. Garages (passenger vehicles only)
1.9
40
Note a
Note a
Trucks & buses
See Section
See Section
See Section
See Section
1607.6 - IBC
1607.6 - IBC
1607.6 - IBC
1607.6 - IBC
9.6
200
---
---
26. Grandstands (see stadium and
---
---
---
---
arena bleachers)
27. Guard House
3.6
75
---
---
28. Gymnasiums, main floors and
4.8
100
---
---
balconies
29. Handrails, guards and grab bars
Section
Section
Section
Section
1607.7 - IBC
1607.7 - IBC
1607.7 - IBC
1607.7 - IBC
30. Hospitals
Operating rooms, laboratories
2.9
60
4.45
1,000
Private rooms
1.9
40
4.45
1,000
Wards
1.9
40
4.45
1,000
Corridors above first floor
3.8
80
4.45
1,000
31. Hotels (see residential)
---
---
---
---
32. Incinerators; charging room
7.2
150
---
---
33. Laboratories, normal scientific
6.0
125
---
---
equipment
34. Latrines / Heads / Toilets /
3.6
75
---
---
Washroom
35. Libraries
Reading rooms
60
4.45
2.9
1,000
7.2b
150b
Stack rooms
4.45
1,000
3.8
80
Corridors above first floor
4.45
1,000
36. Manufacturing
Light
6.0
125
8.9
2,000
Heavy
12.0
250
13.34
3,000
3.6
75
---
---
38. Mechanical equipment room
(general)
4.8
100
---
---
39. Mechanical room (HVAC)
6.0
125
---
---
B-2