APPENDIX A. U.S. ARMY CORPS OF ENGINEERS LIST OF APPROVED STANDING SEAM METAL ROOF SYSTEMS
IN ACCORDANCE WITH CEGS 07416 (Oct. 1991)
Design Load
Design Load
Date of
System
Panel Span
Width
Gage No.
Based on
Based on
Manufacturer
Approval
Deformation1
Failure2
Name
(psf)
(psf)
34.6 - 64.4*
33.8 - 64.1*
MR-24
5' - 1"
24"
24-22
Butler Co.
02-13-92
53.8 -127.3*
59.0 - 110.1*
2' - 6 "
24-22
VSR
5' - 1"
16"
24
36.4
39.2
Butler Co.
07-22-92
2' - 6 "
24
65.9
66.2
CRP-16
5' - 1"
16"
24
42.0
38.8
CECO
10-01-92
2 ' - 6 "
24
76.8
66.8
SEAM-LOC 24
5' - 0"
24"
24
32.1
32.2
Metal Sales
11-23-92
2' - 6"
24
46.8
47.6
Mfg. Co.
BattenLok
5' - 0"
16"
24
38.4
31.0
MBCI
12-14-92
43.9 - 58.8*
43.3 - 70.1*
2' - 6"
24
StarShield
5' - 0"
24"
24
48.0
44.1
Star Bldg
02-05-93
2' - 6"
24
72.0
56.7
Systems
Shur-Lok
5'
-
0"
24"
24
--
42.8
Gulf States
06-16-93
4'
-
0"
24"
24
--
50.3
Mfg. Co.
2'
-
6"
24"
24
--
80.0
1'
-
8"
24"
24
--
84.9
44.0 - 68.0*
41.0 - 54.0*
VP SSR
5' - 0"
24"
24-22
Varco-Pruden
06-28-93
72.0 - 96.0*
65.0 - 85.0*
2' - 6"
24"
24-22
Buildings
1' - 8"
24"
24-22
60.0
126.0
264FL
5 '- 0"
16"
24
51.2
40.3
Steelox Roofing
07-01-93
2 '- 6"
16"
24
88.0
69.3
Sys.
*
REMARKS
See test results.
1
2
Test load with safety factor of 1.3 applied.
Test load with safety factor of 1.65 applied
Notes:
11