Attachment 12
Figure A12.4. Army Rotary-Wing Mooring Points Layout.
A12.2.4. Installation.
A12.2.4.1. Mooring Points for New Rigid Pavement Equal to or Greater Than 150 Millimeters [6
Inches] Thick. Mooring points for new rigid pavements will be provided by embedding the
mooring devices in fresh Portland cement concrete (PCC). The layout of points is shown in Figure
A12.3 with mooring points at least 600 millimeters [2 feet] from the new pavement joints. This
A12-6