UFC 3-110-03
26 September 2006
Table 2-1. Construction Detail Limitations For Low Slope Roofing
NRCA Detail
Comments
BUR-4
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
BUR 4S
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
BUR 7A.
Do not use.
BUR-7AS
Do not use.
MB-4
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
MB-4S
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
MB-7A
Do not use.
MB-7AS
Do not use.
TS-4
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
TS-4S
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
TS-5
Termination Bar holes must be slotted for expansion and contraction.
TS-5S
Termination Bar holes must be slotted for expansion and contraction.
TS-7B
Do not use.
TS-7BS
Do not use.
SPF-4
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
SPF-4S
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
SPF-5AS
Lightweight insulating concrete not applicable.
SPF-7A
Do not use.
SPF 7AS
Do not use.
SPF-2 (FB)
Fleece-backed membrane not applicable.
SPF-5 (FB)
Fleece-backed membrane not applicable.
SPF-6 (FB)
Fleece-backed membrane not applicable.
SPF-11 (FB)
Fleece-backed membrane not applicable.
SPF-18 (FB)
Fleece-backed membrane not applicable.
SPF-20 (FB)
Fleece-backed membrane not applicable.
SPF-TABLE 2.2
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
Table 2.2
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
TP-4
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
TP-4S
For use only with concrete parapet walls where installation of a reglet and counter
flashing inserted into the reglet joint is not possible.
TP-5
Termination Bar holes must be slotted for expansion and contraction.
TP-5S
Termination Bar holes must be slotted for expansion and contraction.
TP-7A
Do not use.
TP-7AS
Do not use.
14