UFC 1-200-01
20 June 2005
Use Chapter 32.
2-33
CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION.
Delete the chapter.
2-34
CHAPTER 34 EXISTING STRUCTURES.
Use Chapter 34, except as modified below, and UFC 3-600-01. If any conflict occurs
between Chapter 34 and UFC 3-600-01, the requirements of UFC 3-600-01 take
precedence.
2-34.1
Existing buildings inside the United States, its territories and possessions
must comply with ICSSC RP6 / NISTIR 6762 in addition to Chapter 34. Refer to
individual military service standards for specific seismic requirements for existing
buildings outside the United States.
2-34.2
Seismic evaluation of existing buildings must be in accordance with ASCE
31-03. Rehabilitation of existing buildings for seismic loads must be in accordance with
FEMA 356.
2-35
CHAPTER 35 REFERENCED STANDARDS.
Use Chapter 35 and Appendix A.